EasyManua.ls Logo

Texecom Premier 816 - Double EOL; Zone Doubling; Triple EOL

Texecom Premier 816
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier 412/816/832 Installation Manual Installation
INS159-13 17
Double EOL
Use this wiring configuration when connecting detection devices to
a zone that requires alarm/tamper monitoring. Ensure that the zone
is programmed for Double EOL operation (see page 27). The zone
must be wired as follows:
Zone Doubling
This wiring option allows you to wire two detection devices into one
set of zone connections. However, the system will treat each device,
as if it were connected to a separate zone, i.e., each device is fully
programmable.
When using this configuration, the system must be fitted with
the appropriate keypad, Premier RKP16 on the Premier 816
and the Premier RKP8 on the Premier 412.
When a zone is configured for “Zone Doubled” it must be wired as
follows:
The following table shows how each physical zone is mapped when
using the “Zone Doubled” configuration:
Premier 412
Panel Zone
Zone A
Zone B
1
1
5
2
2
6
3
3
7
4
4
8
Premier 816/832
Panel Zone
Zone A
Zone B
1
1
9
2
2
10
3
3
11
4
4
12
5
5
13
6
6
14
7
7
15
8
8
16
Zones above 9 on either the Premier 8X/8XE Expander MUST
not be configured for “Zone Doubled”.
The Premier 8X/8XE Expander cannot be used on the Premier
816/832 control panels if any of zones 1 - 8 are configured as
“Zone Doubled”.
Triple EOL
This wiring option is designed to be used with Texecom detectors
that support Triple EOL (T-EOL) wiring. Ensure that the zone is
programmed for Triple EOL operation (see page 27). The zone must
be wired as follows:

Table of Contents

Other manuals for Texecom Premier 816

Related product manuals