Premier 412/816/832 Installation Manual Programming the Control Panel
INS159-13 49
 Double Pulse on Arming
This output type activates twice (2 seconds on) when the selected
Partition is armed.
 Chime
This output type activates for 2 seconds when a zone programmed
as Chime is violated in the selected Partition.
 Door Strike
This output type activates for 2 seconds when an Access code with
the “Activate Door Strike Output” attribute is entered.
 Cross Zone Time Active
This output type activates when a Cross Zone is violated and
remains active for the duration of the Cross Zone Time Window.
 Single Pulse on Disarming
This output type activates for 2 seconds when the selected Partition
is disarmed.
 Reset Required
This output type activates when an alarm condition requires
resetting in the selected Partition.
 Acknowledgement Required
This output type activates when a Service Fault requires
acknowledgement.
 Confirmed Alarm
This output type activates when two different zones are violated
during an armed period.
 Alarm Abort
This output type activates when the system is disarmed after an
alarm condition (providing the system is disarmed before the “Alarm
Transmission Abort” delay has expired, see page 35).
 Away Armed
This output type activates when the partition is “Away Armed”.
 Away Armed/Exit
This output type activates when the partition is in exit mode (Away
arming) and when the partition is “Away Armed”.
 Detector Latch
This output type is used to latch an alarm condition on detectors
that have a latch input.
 Armed/Alarm
This output type is used to indicate both the armed and alarm status
of a partition, it operates as follows: on = armed; off = disarmed;
pulsing = alarm.
 Arm Failed
This output type activates when the selected partition fails to arm.
 All Armed
This output activates when all selected partitions are armed. It
resets when any of the selected partitions is disarmed.
Group Zone Output Types
This group contains the zone output types as listed below:
 -  Zone 01 - 32 Mimic
This output type activates when Zone XX is violated and deactivates
when the zone is secure.
 -  Zone 01 - 32 Alarm
This output type activates when Zone XX causes an alarm and
deactivates when the alarm is reset.
Output Attributes
Each output can have the following attributes assigned to alter the
function of the selected output:
 Enable for Partition 1
On: The selected output is assigned to Partition 1.
Off: The selected output is not assigned to Partition 1.
 Enable for Partition 2
On: The selected output is assigned to Partition 2.
Off: The selected output is not assigned to Partition 2.
 Enable for Partition 3 (Premier 816/832 Only)
On: The selected output is assigned to Partition 3.
Off: The selected output is not assigned to Partition 3.
 Enable for Partition 4 (Premier 816/832 Only)
On: The selected output is assigned to Partition 4.
Off: The selected output is not assigned to Partition 4.
 Enable for User Test
On: The selected output is activated during a user test.
Off: The selected output is not activated during a user test.
 Inverted
On: The selected output is inverted.
Off: The selected output is normal.
 Latching
On: The selected output will latch on until the system is reset.
Off: The selected output will not latch.
 Pulsed
On: The selected output will pulse for the duration of the Output
Short Pulse Timer (see page 35).
Off: The selected output will be normal.