Premier 412/816/832 Installation Manual Programming the Control Panel
INS159-13 43
Entry Tones from Keypad
On: The internal sounder for the selected keypad will produce
Entry tones.
Off: Entry tones will not be produced.
Keypad Options 4
The operation of Keypad Options 4 is described as follows:
Enable Keypad Zones
On: The zones onboard the selected remote keypad are enabled
and allocated as follows:
Off: The zones onboard the selected remote keypad are disabled:
This option is only relevant if the keypad type is a Premier
RKP8/16 Plus or Premier LCD.
If the system is fitted with either a local or remote expander,
the relevant zones on the expander will be disabled if the
zones on the remote keypad are enabled.
Disable Keypad Lid Tamper
On: The remote keypad lid tamper is not monitored.
Off: The remote keypad lid tamper is monitored.
Zone Shift by 4
On: The remote keypad zone status lights indicate from Zone 5
onwards i.e., Zone 1 on the remote keypad follows the status
of Zone 5 and Zone 2 on the remote keypad follows the
status of Zone 6 etc.
Off: The remote keypad zone status lights indicate as normal.
Zone Shift by 8
On: The remote keypad zone status lights indicate from Zone 9
onwards i.e., Zone 1 on the remote keypad follows the status
of Zone 9 and Zone 2 on the remote keypad follows the
status of Zone 10 etc.
Off: The remote keypad zone status lights indicate as normal.
Zone Shift by 16
On: The remote keypad zone status lights indicate from Zone 17
onwards i.e., Zone 1 on the remote keypad follows the status
of Zone 17 and Zone 2 on the remote keypad follows the
status of Zone 18 etc.
Off: The remote keypad zone status lights indicate as normal.
Options 3, 4 and 5 allow the Premier RKP4 remote keypad to
be used on a multi-partition system with more than 4 zones
and the Premier RKP8 remote keypad to be used on a multi-
partition system with more than 8 zones. The example below
shows how a 16 zone system split into 2 partitions could use
two Premier RKP 8 remote keypads: