Premier 412/816/832 Installation Manual Programming the Control Panel
INS159-13 47
Panel Outputs 
This menu option allows you to program the eight control panel
outputs.
Fast Format/Speech Channels 
When using the Fast Format communication protocol (see page 53)
the channels that are reported to the Alarm Receiving Centre must
be programmed for the relevant conditions. This menu option
allows you to program the eight channels that are used by the Fast
Format protocol.
Expander 1 Outputs 
The Premier 8X remote expander has two programmable outputs.
This menu option allows you to program the outputs of expander 1.
Expander 2 Outputs 
The Premier 8X remote expander has two programmable outputs.
This menu option allows you to program the outputs of expander 2
(Premier 832 Only).
Expander 3 Outputs 
The Premier 8X remote expander has two programmable outputs.
This menu option allows you to program the outputs of expander 3
(Premier 832 Only).
Keypad Outputs 
Both the Premier LCD and LCDL remote keypads have a
programmable output. This menu option allows you to program the
keypad outputs.
Output Groups and Types
Group - Not Used
This group contains no output types, by assigning an output to this
group the output will never activate.
Group - System Output Types
This group contains the system output types as listed below:
 Courtesy
This output type activates after any keypad has been used and
during entry delay. The output will remain active for the duration of
the Courtesy timer (see page 36).
 Successful Transmission
This output type activates after the communicator has successfully
reported to the alarm receiving centre.
 Log 80% Full
This output type activates when the Event Log is 80% full. The
output is cleared when the event log is uploaded by the remote
downloading computer.
 Program Mode Selected
This output type activates when the program mode is selected.
 Download in Progress
This output type activates when a Download is in progress.
 Timed Arming Countdown
This output type activates when the system initiates a timed arm.
 Zone Soak Test Active
This output type activates when any zone is enabled for soak test.
 Zone Soak Test Failed
This output type activates if any zone fails during a zone soak test.
 Latched AC Fail
This output type activates when the mains supply is disconnected.
 Telephone Line Fault
This output type activates when the communicator detects a
telephone line fault.
 Smoke Alarm
This output type activates when a 2-wire smoke detector connected
to Panel Output 1 causes an alarm.
 Box/Auxiliary Tamper Alarm
This output type activates when the box tamper or the Auxiliary
Input (Tamper) on the main panel causes an alarm.
 Date/Time Loss
This output type activates when the control panel real time clock is
reset (power up). The output clears when the clock is set.
 Zone Trouble/Tamper
This output type activates when any zone is in trouble or tamper.
 Keypad Tamper/Removed
This output type activates when a keypad is either disconnected or
its box tamper causes an alarm.
 Service Fault
This output type activates when there are any Service Faults on the
system (mimics the Service light on the remote keypad).
 Output 1 Fault
This output type activates when Panel Output 1 detects a fault.
 Output 2 Fault
This output type activates when Panel Output 2 detects a fault.
 Siren/Bell Fault
This output type activates when Siren Output detects a fault.
 Smoke Sensor Fault
This output type activates when a 2-wire smoke detector connected
to Panel Output 1 causes a fault.
 Auxiliary Fuse Fault
This output type activates when the Auxiliary fuse is ruptured.
 Latched Battery Fault
This output type activates when the system detects a fault from the
stand-by battery.
 Service Required/Test Fail
This output type activates when a Service Required fault exists or
the system has failed zone soak test.
 Fail to Communicate
This output type activates after the communicator has failed to
report to the alarm receiving centre.
 Control Timer 1 Active
This output type activates when Control Timer 1 is active.
 Control Timer 2 Active
This output type activates when Control Timer 2 is active.
 Control Timer 3 Active
This output type activates when Control Timer 3 is active.
 Control Timer 4 Active
This output type activates when Control Timer 4 is active.
 PC Output 1
The remote Downloading computer controls this output type.
 PC Output 2
The remote Downloading computer controls this output type.