Premier 412/816/832 Installation Manual Commissioning & Troubleshooting
INS159-13 21
The Speaker Output Does Not Work
The expander can be configured so that the alarm, entry, exit,
chime tones etc. can be enabled or disabled. Check that the
expander has been programmed correctly, see page 44 for
details.
The speaker volume on the expander is electronically
adjustable. Check the volume is set to the desired level, see
page 44 for details.
Zones
One or More Zones Show an Alarm
Each zone on the system can be configured for different wiring
options. Check that the zones are programmed for the correct
wiring configuration, see page 27 for further details.
Check that the zone is wired correctly, see page 15 for further
details.
Service Faults
If the Service light is on or flashing then the system has detected
one or more fault conditions, for details on how to view and
acknowledge Service Faults see page 75.
On Power-Up the Service Light is On
When the system is powered-up the system date and time are
incorrect. This will cause a Date/Time Loss fault, to clear this
fault, program the system date and time, see page 69.
If the battery presence check is enabled the system will check
the battery every 30 seconds. If the system does not have a
battery connected then a battery fault will be generated. To
clear this fault either connect a battery or disable the battery
presence check, see page 36.
Panel outputs 1 and 2 are supervised outputs, if you have not
connected a device to either of these outputs the system will
generate an output fault. To clear this fault either fit 1K load
resistors between the outputs and +12V, see page 19 or
disable the monitoring of outputs 1 and 2, see page 38.
The Siren output is a supervised output, if you have not
connected a device to this output the system will generate a
siren fault. To clear this fault either fit 1K load resistors between
the siren terminals, see page 19 or disable the monitoring of
the siren output, see page 38.
Communicator
The Communicator Will Not Dial
By default the communicator is disabled, check that the
communicator is enabled, see page 52.
Check that the telephone line has been correctly wired to the
control panel.
Check that the primary telephone number is programmed
correctly, see page 52.
Check that the primary account number is programmed
correctly, see page 53.
Check that the primary protocol is programmed correctly, see
page 53.
Check that the primary dial attempts is not programmed as
zero, see page 53.
Check that the primary reporting partitions have been
programmed correctly, see page 53.
Check that the primary reporting options have been
programmed correctly, see page 54.
Communicator Dials But Does Not Communicate
Check that the primary telephone number is programmed
correctly, see page 52.
Check that the primary account number is programmed
correctly, see page 53.
Check that the primary protocol is programmed correctly, see
page 53.
If you are using either Pulse or Express formats check that the
protocol is configured correctly, see page 54.
Operation
The System Will Not Allow Arming
Check that there are no outstanding Service Faults, see page 75.
Check that there are no outstanding alarms that require
resetting, see page 75.
Check that the User code has been programmed to allow
arming, see page 66.
Check that the User code has been assigned to the correct
partition(s), see page 66.
If the User code is programmed for Local Partition Access
Only” (see page 67) then ensure that the keypad that is being
used is assigned to the correct partition, see page 42.
The System Will Not Allow Disarming
Check that the User code has been programmed to allow
disarming, see page 66.
Check that the User code has been assigned to the correct
partition(s), see page 66.
If the User code is programmed for Local Partition Access
Only” (see page 67) then ensure that the keypad that is being
used is assigned to the correct partition, see page 42.