Premier 412/816/832 Installation Manual Programming the Control Panel
INS159-13 39
Disable Open/Close Reporting on STAY Arm
On: Open and Close events are not reported to the Alarm
Receiving Centre when Stay arming the system/partition.
Off: Open and Close events are reported when Stay arming the
system/partition.
Cross/Double Knock Timer is in Minutes
On: System timer 02 “Cross Zone Time Window” is counted in
minutes.
Off: System timer 02 “Cross Zone Time Window” is counted in
seconds.
Disable Zone Bypass when Armed
On: The user cannot bypass zones in an armed partition. Only
zones that are unarmed can be selected for bypass.
Off: The user can bypass zones in an armed partition.
Activated Zones Cause Alarm during Exit
On: If a non “delay” or “follower” zone is activated during exit
mode the panel will generate a full alarm condition.
Off: If a non “delay” or “follower” zone is activated during exit
mode the panel will generate a fault condition.
Control Timer 4 Performs Battery Test
On: Control Timer 4 is used to perform the dynamic battery test,
i.e. when the timer switches on the panel will allow the stand-
by battery to power the system for 1 minute.
Off: Control Timer 4 behaves as normal.
Miscellaneous Options 2 -
The function of each option is described as follows:
Disable Service Fault Acknowledgement
On: When a Service Fault occurs the system can be armed
without the need to acknowledge the fault condition.
Off: All Service Faults require acknowledgment before the system
can be armed.
Enable User Reset for Alarms
On: Any user can reset alarms and troubles.
Off: Alarms and troubles can only be reset by users with the
“Allow Alarm/Fault Acknowledgement” attribute (see User
Options 3 on page 67).
Disable Online Printing
On: The online printer port (Com1) will not send real time event
data.
Off: The online printer port (Com1) will send real time event data.
Enable Bell Module and UK Options
On: When the system is fitted with a Premier Bell Module this
option must be enabled (this module is only used in the UK).
Also the following UK options are enabled:
All alarm zones and tampers are disabled whilst in
engineers programming mode
After entering the engineers passcode, the Strobe output
on the Premier Bell Module pulses 3 times, this invokes
the Engineer Hold Off mode if a Texecom Odyssey bell
box is connected
Off: The Premier Bell Module and UK options are disabled.
Enable DD 243:2002 Options
On: The Confirmation output is disabled once the Entry Timer is
started, i.e. during the Entry Time, activation of a second
(different) zone will NOT activate the Confirmation output.
Off: The Confirmation output operates as normal.
To comply with DD 243:2002 this option must be enabled if
access to the protected premises initiates the entry timer.
Owing to the ability to disable ALL of the confirmation facilities,
the customer should be advised in writing by the alarm
company that ALL means of alarm confirmation are disabled
when the initial entry door is opened. The alarm company
should then obtain written acceptance from the customer of the
disabling of the means of alarm confirmation.
Enable Confirmation After Entry Time-Out
On: If option 5 (above) is enabled the Confirmation output is
ONLY disabled for the duration of the Entry Time and re-
enabled once the Entry Timer has expired, i.e. after the Entry
Timer has expired, further activation of two different zones
WILL activate the Confirmation output.
Off: If option 5 (above) is enabled the Confirmation output
remains disabled once the Entry Timer is started.
To comply with DD 243:2004 this option can only be enabled
if the system is unset by a single action device such as a
Swipe Card, Radio FOB, Infra-Red FOB, Proximity Card etc.
Invert Auxiliary Input Operation
On: The operation of the auxiliary input is inverted and operates
as shown in the table below: