Programming Worksheets & Defaults Premier 412/816/832 Installation Manual
98 INS159-13
Menu: 
Non Zone Alarm/Restore Codes
Page 63
Event No
Event Type
Event
Reporting Group
Pulse/Express
Contact ID
SIA
52
Soak Test
Alarm
Test
[ ] [ ] 00
53
Restore
-
-
-
-
54
Fire Zone Trouble
Alarm
Tamper
[ ] [ ] 00
373
FT
55
Restore
Restore
[ ] [ ] 00
373
FJ
56
System Power Up
Alarm
Maintenance
[ ] [ ] 00
57
Restore
-
-
-
-
58
Swinger Shutdown (Zone No)
Alarm
Alarm
[ ] [ ] 00
59
Restore
-
-
-
-
60
User Code Entered
Alarm
-
-
-
-
61
Restore
-
-
-
-
62
Exit Started
Alarm
-
-
-
-
63
Restore
-
-
-
-
64
Entry Started
Alarm
-
-
-
-
65
Restore
-
-
-
-
66
Bell Active
Alarm
-
-
-
-
67
Restore
-
-
-
-
68
Alarm Active
Alarm
-
-
-
-
69
Restore
-
-
-
-
70
Keypad Tamper
Alarm
Tamper
[ ] [ ] 3*
137
TA
71
Restore
-
-
-
-
72
Keypad Medical
Alarm
Priority Alarm
[ ] [ ] 00
100
MA
73
Restore
-
-
-
-
74
Keypad Fire/2-Wire Smoke
Alarm
Priority Alarm
[ ] [ ] 00
115
FA
75
Restore
Restore
[ ] [ ] 00
115
FH
76
Duress Code Alarm
Alarm
Priority Alarm
[ ] [ ] 00
121
HA
77
Restore
-
-
-
-
78
Keypad Silent PA
Alarm
Priority Alarm
[ ] [ ] 2*
122
PA
79
Restore
-
-
-
-
80
Keypad Audible PA/Auxiliary PA
Alarm
Priority Alarm
[ ] [ ] 2*
120
PA
81
Restore
Restore
[ ] [ ] 00
120
PH
82
Box Tamper
Alarm
Tamper
[ ] [ ] 30
137
TA
83
Restore
Restore
[ ] [ ] 00
137
TR
84
Zone Tamper
Alarm
Tamper
[ ] [ ] 3*
144
TA
85
Restore
Restore
[ ] [ ] 00
144
TR
86
Zone Trouble
Alarm
Tamper
[ ] [ ] 00
380
UT
87
Restore
Restore
[ ] [ ] 00
380
UJ
88
Expander/Remote Trouble
Alarm
Tamper
[ ] [ ] 00
333
ET
89
Restore
-
-
-
-
90
Auxiliary Tamper Input
Alarm
Tamper
[ ] [ ] 30
137
TA
91
Restore
Restore
[ ] [ ] 00
137
TR
92
Date Changed
Alarm
Maintenance
[ ] [ ] 00
625
JD
93
Restore
-
-
-
-
94
Time Changed
Alarm
Maintenance
[ ] [ ] 00
625
JT
95
Restore
-
-
-
-
96
System Reset
Alarm
Maintenance
[ ] [ ] 00
97
Restore
-
-
-
-
98
Remote Control
Alarm
Test
[ ] [ ] 00
-
-
99
Restore
Restore
[ ] [ ] 00
-
-
100
Confirmed Alarm
Alarm
Alarm
[ ] [ ] 00
139
BV
101
Restore
-
-
-
-
102
Monitored Alarm
Alarm
Alarm
[ ] [ ] 00
220
BA
103
Restore
Restore
[ ] [ ] 00
220
BH
104
FOB Low Battery
Alarm
Maintenance
[ ] [ ] 00
384
XT
105
Restore
-
[ ] [ ] 00
-
-
106
Radio Supervision
Alarm
Maintenance
[ ] [ ] 00
355
YS
107
Radio Supervision
Restore
Maintenance
[ ] [ ] 00
-
YT
108
Communication Port
Alarm
Maintenance
[ ] [ ] 00
356
ET
109
Restore
-
[ ] [ ] 00
-
-