iCNC PERFORMANCE
3-14 OPERATION Manual 0-5399
3.7.5 Ignition On/Off/Auto
ON position will activate the igniter.
AUTO position will allow the cutting program to activate the igniter when necessary.
OFF position will prevent the cutting program from activating the igniter.
3.7.6 Auto Height On/Off/Auto
ON position will activate the capacitive height sensing.
AUTO position will allow the cutting program to activate the capacitive height sensing when necessary.
OFF position will prevent the cutting program from activating the capacitive height sensing.
3.7.7 Cutting Oxygen On/Off/Auto
ON position will open the cutting oxygen solenoid
AUTO position will allow the cutting program to open the cutting oxygen solenoid when necessary
OFF position will prevent the cutting program from opening the cutting oxygen solenoid valve.
3.8 Starting Procedure
Switch on the system by pressing the power button located on the far left hand side of the unit for 5 seconds. When power is applied,
the iCNC Performance will take approximately 1-2 minutes to go through internal diagnostics and fully boot up. After full power up, the
Promotion Work Screen displaying Promotion Cut, Next Job Preview and Current Job along with Info (System Status) will be displayed.
In addition, you will see the yellow Zero button flashing. This will stop automatically.
HINT: The flashing Zero button indicates that the second CPU (used for machine motion) has booted up correctly. The Zero button flashes
41 times.
Turn ON the drive enable the drive enable to enable the drives. A dialog box may appear START HOMING PROCEDURE.
3.8.1. Shutting Off / Removing Power
After locating a safe parked position, disable the drives by turning the drive enable to OFF. Turn off the controller using the normal
Windows shutdown method. Click on Start (bottom left hand corner) on Window’s task bar, then click Shut down.
After the controller goes through a proper cycle down procedure the controller will turn off.
HINT: If applicable, parking the machine near the homing switches will make Machine Homing quick and easy when the iCNC Perfor-