APPENDIX 60 Manual 0-2568
APPENDIX VII: INTERFACE CABLE FOR STANDOFF
CONTROL (SC11)
A-01433
J41
Standoff Control
SC11
Merlin 3000 or
Merlin 6000
Remote Cable
J15
6
8
7
9
+48 VDC
1A
48 VDC
Common
J15
J42
J41
Black
Red
White
Green
10
11
24
25
28
29
19
3
4
1
2
12
14
3
4
5
6
13
OK-To-Move
Torch Volts
Signal
START/STOP
Orange
Blue
Yellow
Brown
Violet
Gray
Shield Drain
-
+
J42