MEC 310 GENSET CONTROLLER -
Option J – CANbus J1939
PM077 R1 09/08/20 Page 13 THOMSON TECHNOLOGY
Views available on the display
Object DDEC EMR JDEC Volvo
Penta
Scania
EMS
Speed Available Available Available Available Available
Coolant temp. Available Available Available Available Available
Oil pressure Available Available Available Available Available
EIC: Faults N. A. Available N. A. N. A. N. A.
EIC: Oil temp. Available N. A. N. A. Available Available
EIC: Fuel temp. Available N. A. Available N. A. N. A.
EIC: Boost pressure Available N. A. N. A. Available Available
EIC: Air inlet temp. Available N. A. N. A. N. A. N. A.
EIC: Coolant level Available N. A. N. A. Available Available
EIC: Fuel rate Available N. A. Available Available Available
EIC: Charge air pressure N. A. N. A. N. A. N. A. N. A.
EIC: Charge air temp. N. A. N. A. Available Available Available
EIC: Air inlet pressure N. A. N. A. N. A. Available N. A.
EIC: Exhaust gas temp. N. A. N. A. N. A. Available N. A.
EIC: Engine hours N. A. N. A. N. A. Available N. A.
EIC: Oil f. diff. press. N. A. N. A. N. A. Available N. A.
EIC: Battery voltage N. A. N. A. N. A. Available N. A.
EIC: Fuel del. press. N. A. N. A. N. A. Available N. A.
EIC: Oil level N. A. N. A. N. A. Available N. A.
EIC: Crankcase press. N. A. N. A. N. A. Available N. A.
EIC: Coolant pressure N. A. N. A. N. A. Available N. A.
EIC: Water in. fuel N. A. N. A. N. A. Available N. A.
•
All the display values corresponding to this option J have a description
beginning with ‘EIC’.
•
If a view line is not available, it will not be shown.
•
If the value for an available view line is not available due to some type of
error in the sensor, sub-system or module, ‘--’ is shown.
•
If the value for an available view line is not available (e.g. due to a
communication error), the value field is exchanged with ‘—’.
•
The menu 6001 (Engine I. Comm.) is affecting the shown value on the
display.