© 2016 Thorlabs Scientific Imaging94
DCx Camera Functional Description and SDK Manual
cameras that you are operating in the fast live mode. Not all camera models support this mode
(see is_SetExternalTrigger()).
Notes
The freerun synchronization mode is currently not supported by DCx Cameras.
In trigger mode, the maximum frame rate is lower than in freerun mode because the sensors
expose and transfer sequentially. The possible frame rate in trigger mode depends on the
exposure time.
Example: At the maximum exposure time, the frame rate is about half as high as in freerun mode;
at the minimum exposure time, the frame rate is about the same.