DCx Camera Functional Description and SDK Manual
Contents of the IS_DEVICE_INFO::IS_DEVICE_INFO_CONTROL structure
Internal device ID of the camera
Return values
One of the submitted parameters is outside the
valid range or is not supported for this sensor or
is not available in this mode.
An IO request from the uc480 driver failed.
Possibly the versions of the uc480.dll (API) and
the driver file (uc480_usb.sys) do not match.
Function executed successfully
Related functions
is_GetCameraList()
Example 1
// The camera has the device ID 1
UINT nDeviceId = 1;
IS_DEVICE_INFO deviceInfo;
memset(&deviceInfo, 0, sizeof(IS_DEVICE_INFO));
INT nRet = is_DeviceInfo((HIDS)(nDeviceId | IS_USE_DEVICE_ID),
IS_DEVICE_INFO_CMD_GET_DEVICE_INFO,
(void*)&deviceInfo, sizeof(deviceInfo));
if (nRet == IS_SUCCESS)
{
WORD wTemperature = deviceInfo.infoDevHeartbeat.wTemperature;
}