Description
israw_InitFile() initializes an instance of the uEye RAW interface. Multiple instances can be
created simultaneously.
Input parameters
Pointer in which the instance ID is returned. This ID is
needed for calling other functions.
File access mode:
Read: IS_FILE_ACCESS_MODE_READ
Write: IS_FILE_ACCESS_MODE_WRITE
Return values
IS_AVI_NO_ERR
No error, function executed successfully.
IS_AVI_ERR_EXCEPTION
An error has occurred.
IS_AVI_ERR_GENERIC
Generic error
IS_AVI_ERR_PARAMETER
One of the submitted parameters is outside the
valid range.
IS_AVI_ERR_NEW_FAILED
The maximum number of instances have been
reached.
Related functions
israw_ExitFile()
4.5.8 israw_OpenFile
USB 2.0
USB 3.0
GigE
-
Syntax
INT israw_OpenFile(UINT unFileID, const char* strFileName)
Description
israw_OpenFile() opens a new or existing RAW file.
Input parameters
Instance ID set by the israw_InitFile() function
RAW file name
Return values
IS_AVI_NO_ERR
No error, function executed successfully.
IS_AVI_ERR_EXCEPTION
An error has occurred.
IS_AVI_ERR_FILE_NOT_OPEN
The file is not open.
IS_AVI_ERR_GENERIC
Generic error
IS_AVI_ERR_INVALID_ID
The indicated instance could not be found.
Either the ID is invalid or the instance has

Table of Contents

Other manuals for THORLABS DCU223 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223 SERIES and is the answer not in the manual?

THORLABS DCU223 SERIES Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223 SERIES
CategorySecurity Camera
LanguageEnglish

Related product manuals