4 Programming (SDK)
255
4.3.53 is_GetTestImageValueRange
USB 2.0
USB 3.0
USB 2.0
USB 3.0
Syntax
INT is_GetTestImageValueRange (HIDS hCam,
INT TestImage,
INT* TestImageValueMin,
INT* TestImageValueMax)
Description
Using is_GetTestImageValueRange(), you can query the value range of the additional parameter
required for some camera test images. You can enable the sensor test image feature using
is_SetSensorTestImage().
Input parameters
hCam
Camera handle
TestImage
Test image for which the value range is queried
TestImageValueMin
Minimum value
TestImageValueMax
Maximum value
Return values
IS_INVALID_CAMERA_HANDLE
Invalid camera handle
IS_NO_SUCCESS
General error message
IS_NOT_SUPPORTED
The camera model used here does not support
this function or setting.
In this case, the TestImageValueMin and
TestImageValueMax parameters are equal to 0.
IS_SUCCESS
Function executed successfully
Related functions
is_GetSupportedTestImages()
is_SetSensorTestImage()

Table of Contents

Other manuals for THORLABS DCU223 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223 SERIES and is the answer not in the manual?

THORLABS DCU223 SERIES Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223 SERIES
CategorySecurity Camera
LanguageEnglish

Related product manuals