© 2016 Thorlabs Scientific Imaging380
DCx Camera Functional Description and SDK Manual
4.3.99 is_SetTriggerCounter
USB 2.0
USB 2.0
Syntax
INT is_SetTriggerCounter (HIDS hCam, INT nValue)
Description
is_SetTriggerCounter() returns the number of images captured in hardware or software trigger
mode.
Note
In freerun mode, the counter always returns 0 even when images were captured.
Input parameters
Camera handle
nValue
IS_GET_TRIGGER_COUNTER
Returns the current count for triggered image
captures
Other values
Resets the counter for triggered image captures
Return values
IS_CANT_COMMUNICATE_WITH_DRIVER
Communication with the driver failed because
no driver has been loaded.
IS_CANT_OPEN_DEVICE
An attempt to initialize or select the camera
failed (no camera connected or initialization
error).
IS_INVALID_CAMERA_HANDLE
Invalid camera handle
IS_INVALID_PARAMETER
One of the submitted parameters is outside the
valid range or is not supported for this sensor or
is not available in this mode.
IS_IO_REQUEST_FAILED
An IO request from the uc480 driver failed.
Possibly the versions of the uc480.dll (API) and
the driver file (uc480_usb.sys) do not match.
IS_NO_SUCCESS
General error message
IS_SUCCESS
Function executed successfully
Related functions
is_SetExternalTrigger()
is_CameraStatus()

Table of Contents

Other manuals for THORLABS DCU223 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223 SERIES and is the answer not in the manual?

THORLABS DCU223 SERIES Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223 SERIES
CategorySecurity Camera
LanguageEnglish

Related product manuals