© 2016 Thorlabs Scientific Imaging256
DCx Camera Functional Description and SDK Manual
4.3.54 is_GetTimeout
USB 2.0
USB 3.0
USB 2.0
USB 3.0
Syntax
INT is_GetTimeout (HIDS hCam, UINT nMode, UINT* pTimeout)
Description
Using is_GetTimeout(), you can read out user-defined timeout values from the uc480 API.
For further information, please refer to the How to proceed: Timeout values for image capture
section.
Input parameters
Camera handle
Selects the timeout value to be returned
Returns the timeout value in steps of 10 ms for triggered
image capture
Pointer to the variable that holds the timeout value. Returns
0 if the default value of the uc480 API is used.
Return values
Invalid camera handle
One of the submitted parameters is outside the valid
range or is not supported for this sensor or is not available
in this mode.
General error message
The camera model used here does not support this
function or setting.
Function executed successfully
Related functions
is_SetTimeout()
is_CaptureVideo()
is_FreezeVideo()
is_SetExternalTrigger()
Example
// Return user-defined timeout
UINT nTimeout;
INT ret = is_GetTimeout(hCam, IS_TRIGGER_TIMEOUT, &nTimeout);

Table of Contents

Other manuals for THORLABS DCU223 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223 SERIES and is the answer not in the manual?

THORLABS DCU223 SERIES Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223 SERIES
CategorySecurity Camera
LanguageEnglish

Related product manuals