4 Programming (SDK)
327
hCam
Camera handle
IS_GET_AUTO_SHUTTER_MAX
Returns the upper limit for auto exposure shutter.
Control parameters
pval1: returns the current setting
IS_SET_AUTO_BRIGHTNESS_ONCE
Enables/disables the automatic disable for
automatic brightness control (gain and exposure
time)
*2
Control parameters
pval1 = 1 enables control, 0 disables control
IS_GET_AUTO_BRIGHTNESS_ONCE
Returns the automatic disable status
*2
Control parameters
pval1: returns the current setting
Speed and hysteresis
IS_SET_AUTO_SPEED
Sets the speed value for the auto function.
Control parameters
pval1: defines the control speed (0...100)
IS_GET_AUTO_SPEED
Returns the speed value for the auto function.
Control parameters
pval1: returns the current setting
IS_SET_AUTO_SKIPFRAMES
Sets the number of frames to be skipped during
automatic control.
Control parameters
pval1: defines the number of frames to be
skipped during automatic control (default: 4)
IS_GET_AUTO_SKIPFRAMES
Returns the number of frames to be skipped
during automatic control.
Control parameters
pval1: returns the current setting
IS_GET_AUTO_SKIPFRAMES_RANGE
Returns the permissible range for the number of
frames to be skipped.
Control parameters
pval1: returns the minimum permitted value
pval2: returns the maximum permitted value
IS_SET_AUTO_HYSTERESIS
Sets the hysteresis value for auto exposure
shutter and auto gain control.
Control parameters
pval1: defines the hysteresis value (default: 2)
IS_GET_AUTO_HYSTERESIS
Returns the hysteresis value for auto exposure
shutter and auto gain control.
Control parameters
pval1: returns the current setting
IS_GET_AUTO_HYSTERESIS_RANGE
Returns the permissible range for the hysteresis
value.
Control parameters
pval1: returns the minimum permitted value

Table of Contents

Other manuals for THORLABS DCU223 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223 SERIES and is the answer not in the manual?

THORLABS DCU223 SERIES Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223 SERIES
CategorySecurity Camera
LanguageEnglish

Related product manuals