Output Type: Non-voltage Contact Point Output 1a Contact Point
Additional
Function
Event Output
Contact Point Capacity: AC250V 2.4A (resistance load)
1, 2
Minimum Applicable Load: DC5V 10mA
Mechanical Life: More than 5 million times
Electrical life: More than 200,000 times
Loader
Communication
Communication
Standard
TTL
Communication
Method
Dedicated Protocol
Communication Speed
9600 BPS
Character
Start Bit 1
Stop Bit 2
Data Length 8
Without Parity
With BCC Check
Address 1
10. Maintenance and Inspection
Trouble
Things To Be Checked
Nothing is displayed on screen
Is the power supply terminal properly connected?
Is the power properly supplied?
Measurement value is not accurate
Is the sensor working normally?
(Have you tried other sensors?)
Is the sensor properly connected?
Is the type of sensor properly configured?
Is the PV correction value correct?
Setting value does not match with
the measurement value
Does the heater have enough capacity?
Is the Integral time setting (I) correct?
Control is insufficient
Is the PID value correct?
Retry autotuning
Set self-tuning
Abnormal output
Is the output terminal properly connected?
Is the control type properly configured?
If you still have questions, please contact our sales office.