HiPer Ga/Gb Configuration
HiPer Ga/Gb Operator’s Manual
3-2
When configuring receivers for RTK surveying, use the following
checklist to ensure the receivers are properly set up:
Perform pre-survey functions as described in Chapter 2.
Configure one receiver as an RTK Base station and the other
receiver as an RTK Rover. See “Configuring the Receiver” on
page 3-7.
Configure the communication data link for transmitting and
receiving corrections. See “Configuring the Radio Modem” on
page 3-3.
Set up the Base receiver over a known point to begin collecting
static observation data and transmitting corrections. Set up the
Rover receiver to begin collecting RTK data. See “Receiver
Setup” on page 4-1 for more information.
When configuring receivers for post-processing surveying, use
the following checklist to ensure the receivers are properly set up:
Perform pre-survey functions as described in Chapter 2.
Configure one receiver as a Base station and the other receiver as
a Rover. See “Configuring the Receiver” on page 3-7.
Set up the Base receiver over a known point to begin collecting
static observation data. Set up the Rover receiver to begin
collecting static or kinematic observation data. See “Receiver
Setup” on page 4-1 for more information.