FusibleLinkHarness
2
1
g275996
Figure188
1.Startermotor
2.Fusiblelinkharness
FUSIBLE LINK (14 GAUGE)
FUSIBLE LINK (16 GAUGE)
P01
STARTER B+
P02
TO MAIN HARNESS
g275997
Figure189
YourGroundsmasterusestwo(2)fusiblelinksforcircuitprotection.These
fusiblelinksarelocatedinaharnessthatconnectsthestarterB+terminalto
thewireharness(Figure188).Ifeitheroftheselinksshouldfail,currenttothe
protectedcircuitswillcease.RefertoAppendixA(pageA–1)forwireharness
drawingsforadditionalfusiblelinkinformation.
Testing
MakesurethatignitionswitchisOFF .Disconnectnegativebatterycablefrom
batteryterminalandthendisconnectpositivecablefrombattery(seeBattery
Service(page6–71)).Locateandunplugfusiblelinkconnectorfrommachine
wireharness.Useamultimetertomakesurethatcontinuityexistsbetweenthe
fusiblelinkterminals.Ifeitherfusiblelinkisopen,replacethefusiblelinkharness.
Note:Itisnotrecommendedtoreplaceindividualfusiblelinkconductorsof
thefusiblelinkharness.Ifanyoftheharnesslinksareopen(failed),replace
theentirefusiblelinkharness.
Afterfusiblelinktestingiscomplete,makesurethatfusiblelinkharnessis
securelyattachedtostarterB+terminalandwireharness.Connectpositive
batterycabletobatteryterminalrstandthenconnectnegativecabletobattery.