HydraulicSolenoidValveCoils
g309817
Figure214
GROUNDSMASTER4500−DSHOWN
1.Deckcontrolmanifold3.Fancontrolmanifold
2.Liftcontrolmanifold4.Twospeedshiftmanifold
Numeroushydraulicsolenoidvalvecoilsareusedonthehydrauliccontrol
manifoldsofGroundsmaster4500−Dand4700−Dmachines.Whenenergized
bytheTECcontroller,thesecoilsprovidehydrauliccircuitcontrol.
Three(3)differentsolenoidvalvecoilsareusedonyourGroundsmaster.Two
(2)ofthesecoilsslideontothesolenoidvalveandaresecuredwithanut.
Additionally,thetwospeedshiftmanifold(item4inFigure214)includesa
solenoidvalvewithanintegralsolenoidcoil.T estingofallofthesecoilscanbe
donewiththecoilremainingonthehydraulicvalve.
Note:Toassistintroubleshooting,identicalsolenoidcoilscanbeexchanged.If
theproblemfollowstheexchangedcoil,aproblemwiththecoillikelyexists.If
theproblemremainsunchanged,somethingotherthanthesolenoidcoilisthe
problemsource(e.g.switch,circuitwiring,hydraulicproblem).
ElectricalSystem:ComponentTesting
Page6–52
Groundsmaster
®
4500-D/4700-D
19245SLRevA