CuttingDeckPositionSwitches
g309635
Figure201
1.Positionswitch
3.Liftarm(#5shown)
2.Switchconnector
Thecuttingdeckpositionswitchesarenormallyopenproximityswitchesthatare
locatedonthetractionunitframe(Figure201).Thesensingplateislocatedon
thecuttingdeckliftarm.TheGroundsmaster4500−Dusestwo(2)cuttingdeck
positionswitches:fordecks4and5.Therearefour(4)deckpositionswitches
ontheGroundsmaster4700−D:fordecks4,5,6and7.
Whenacuttingdeckislowered,thesensingplateislocatedneartheposition
switchandtheswitchcloses.ThisclosedswitchprovidesaninputfortheTEC
controllertoallowtheloweredcuttingdeckstooperate.
SwitchTesting
#4 Deck #1 Deck #5 Deck
#7 Deck
(GM4700)
#6 Deck
(GM4700)
#3
Deck
#2
Deck
g308386
Figure202
CUTTINGDECKLOCATIONS
Groundsmaster
®
4500-D/4700-D
Page6–41
ElectricalSystem:ComponentTesting
19245SLRevA