Testing(continued)
Verifycontinuitybetweenswitchterminals.Replaceswitchiftestingidenties
thatswitchisfaulty.
SWITCHPOSITIONCLOSEDCIRCUITSOPENCIRCUITS
OFF(DOWN)COMB+NCB
COMC+NCC
COMB+NOB
COMC+NOC
ON(UP)COMB+NOB
COMC+NOC
COMB+NCB
COMC+NCC
5.IfPTOswitchtestscorrectlyandcircuitproblemstillexists,checkwire
harness(seeAppendixA(pageA–1)).
6.Aftertestingiscompleted,connectthewireharnessconnectortothePTO
switch.
7.Assembleconsolearm(seeConsoleArm(page8–10)).
ElectricalSystem:ComponentTesting
Page6–32
Groundsmaster
®
4500-D/4700-D
19245SLRevA