TestingtheMowCircuit–ReliefValve(RV1)and(RV2)Pressure
(5610-D)
g216149
Figure128
Testtheperformanceofthemowcontrolmanifoldreliefvalve(RV1)and(RV2)to
ensurethatthemaximumamountofuidisavailabletothecuttingreelmotors
uptothesetreliefpressure.Thistestalsoensuresthatpump(P1)and(P2)are
capableofgeneratingenoughpressuretoopenproperlyfunctioningreliefvalves.
Note:Thefrontcuttingreelcircuitissuppliedbypump(P2)andprotectedby
areliefvalve(RV2)inthemowcontrolmanifold.Therearcuttingreelcircuit
issuppliedbypump(P1)andisprotectedbyreliefvalve(RV1);refertothe
HydraulicFlowDiagrams(5610-D)(page6–32).
SpecialEquipmentRequired:Flowmeterwithpressuregaugethathasatleasta
45L/minute(12gallons/minute)capacity.
Reelmaster
®
5410/5510/5610Series
Page6–123
HydraulicSystem:TestingtheHydraulicSystem
15216SLRevC