60 model 3000 ADMAP-5M AN712 Module User’s Manual
Chapter 5 Application Interface
5
5.7.15 OIS parameter read
<Function>
To read the parameters (OIS parameters) of OIS
<Message format>
Command
Response
15 8 7 0
2
Read No. n (1 to 128)
+00(0x00)
+16(0x10)
+20
(
0x14
+22
(
0x16
+26
(
0x1A
+28
(
0x1C
+30
(
0x1E
+32
(
0x20
+34
(
0x22
+36
(
0x24
Invocation ID (32-bit value)
15 0
Requested data i (4 bytes)
+00(0x00)
+16
(
0x10
+20
(
0x14
+22
(
0x16
Invocation ID (same as for command)
Requested parameter head number: i
0
'AN712 MMS RC '
Status (0)
+24
(
0x18
Status (0)
'AN712 MMS RR '
+26
(
0x1A
By te address
3
0
Requested data i+1
Requested data i+n-1
+30
(
0x1E
0
0
0
Aux. information
transmit source address
Aux. information
transmit source address
+14(0x0E)
+14(0x0E)