80 model 3000 ADMAP-5M AN712 Module User’s Manual
Chapter 5 Application Interface
5
5.9.5 Station status control
<Function>
To control a specified AN712 module
<Message format>
<Response status>
<Note>
A software initialize request may be made only when all the message requests to the
AN712 module have been completed. Requesting software initialize produces a result
equivalent to switching the AN712 module on/off so that, if existing message requests
have not been completed yet, there will be no notice of their completion.
0x0000 Normal end
0x0203 Request inhibited in the present state
15 0
+00(0x00)
+16(0x110)
Station status control instruction (0x8C0y)
Request status (0x0)
Command
Response
15 0
+00(0x00)
+16(0x10)
Station status control response (0x8C8y)
Response status (error code)
y: status control instruction value
Inring request (1)/off-ring request (2)/online
request (3)/standby request (4)/start request
(0xE)/soft initialize request (0xF)
'AN712 SMG RQ '
Byte address
+18(0x112)
'AN712 SMG RQ '
+18(0x12)
Auxiliary information (0x0)
Auxiliary information (0x0)