81
Note:
When selected IBM HOST, Control code will be 「(A2H), |(7CH), 」(A3H)
When selected IBM HOST US, Control code will be (83H), |(7CH), (84H)
When selected IBM HOST or IBM HOST US, Control code will ignore 00H to 1FH
When selected IBM HOST or IBM HOST US, AS/400 PAGES command will be ignored
* Among the PAGES commands, CTRL parameter X'01 'of the horizontal movement command (ESX
1C): Only the relative position movement (right movement) from the current position is supported.
Replace with the specified amount of movement space. Discard the rest.
MANUAL
CODE1
CODE2
CODE3
8.5.18 MAXICODE SPEC
TYPE1:Compatible: Compatible with the current version
TYPE2: Special Spec Special specification
Note: The mode specified by the command may be different from the actual mode, depending on the status
of this parameter. Also, the data transmission method differs partly.
For details, refer to the BA400 Series External Equipment Interface Specification.
8.5.19 CUT MODE
TYPE1: Standard operation Printer will do high performance Cutting.
TYPE2: Special Spec Printer will do Cutting same speed as B-SA