8.5.30 TONE ADJ. <D>
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-10
1
Decimal
Exist
2
0
None
Step
Remarks:
1. Setting a value in the positive (+) direction, the print tone becomes darker. And, setting a value in the
negative (-) direction, the print tone becomes lighter.
+10 (Darker) 0 (Lighter) -10
2. The print tone fine adjustment value (thermal transfer) is the sum of the fine adjustment values set in the
system mode (by key operation) and set by command (from the PC). The max. value is -10 ~ +10. If the
value exceeds the print head rating, it is automatically corrected.
3. The factory default is +0.
8.5.31 RIBBON TORQUE
Normal
Low
8.5.32 FRONT RIBBON MOTOR
The menu structure of FRONT RIBBON MOTOR menu
Menu item
<2>SET PARAMETERS
FRONT RIBBON MOTOR
Normal Torque
Low Torque
8.5.32.1. Normal Torque
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step
Notes:
1. The fine adjustment value is not effective for the reverse rotation.
2. The ribbon motor torque fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is -15 or +10.
8.5.32.2. Low Torque
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+10
-15
1
Decimal
Exist
2
0
None
Step
Notes:
1. The fine adjustment value is not effective for the reverse rotation.
2. The ribbon motor torque fine adjustment value is the sum of the fine adjustment values set in the system
mode (by key operation) and set by command (from the PC). The max. value is -15 or +10.