TAG CHECK
OFF: Error tag detection is not performed.
ON (ID): Error tag detection is performed.
ON (ACCESS PASSWORD): Error tag detection is performed.
Notes:
1. Description of the options
OFF: Error tag detection is disable.
Though a tag is read before writing data on it, data is always written on the tag whatever data is
set as the header data.
ON (ID): Error tag detection is enable.
A tag (EPC area for GEN2 tags) is read before writing data on it, and data is written on the tag
only when the header data is “A5A5”.
ON (ACCESS PASSWORD): Error tag detection is enable.
Error tag detection is enable only for GEN2 tags. The access password
area of a tag is read before writing data on it. Only when the data read
matches the access password setting data, the data is written on the tag.
2. To prevent unauthorized changes of the setting, a password can be set to protect the error tag detection
setting. (For the password setting procedure, see below.)
3. Example of operation when “ON (ACCESS PASSWORD)” is selected
Choose whether or not to enable the auto unlock
function.
When “ON” is selected, locked tags are
automatically unlocked by the access password
and data write is enabled.
Choose whether or not to set the password to
protect the error tag detection setting.
When “OFF” is selected, this menu is ended and
the upper-level menu is displayed.
When “ON” is selected, the password entry
screen is displayed.