e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C © 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
6 - 82
[CC52] Skew adjustment motor (M1) abnormality
[CC60] Punch motor abnormality
* The [CC52] error will be displays when the [ED10] error occurs three times in succession or
during the initial operation.
MJ-1101 (When MJ-6101 is installed)
Is there any paper remaining on the transport path?

YES Remove the paper.
NO
Rotate the skew adjustment motor (M1). Does it rotate smoothly?

NO Fix the mechanism.
YES
Are the skew home position sensor (S2) and its wiring correct?

NO Replace the sensor. Correct the wiring.
YES
Is the wiring between the hole punch control PC board (HP) and skew adjustment motor (M1)
correct?

NO Correct the wiring.
YES
1. Replace the skew adjustment motor (M1).
2. Replace the hole punch control PC board (HP).
MJ-1030 (when MJ-6004 is installed)
Are the punch home position sensor (PI63) and punch motor clock sensor (PI62) working
normally?
 NO  Replace the sensors.
YES
Is the wiring between the sensors and finisher controller PC board correct?
 NO  Correct the wiring.
YES
Is the punching mechanism normal?
 NO  Fix the mechanism.
YES
1. Replace the punch motor (M61).
2. Replace the punch controller PC board.
3. Replace the finisher controller PC board.