180 GX9 ASD Installation and Operation Manual
Preset Speed 11 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F595, this parameter is used to set the start-
time and run-time of Preset Speed 11 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F580
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No
Preset Speed 12 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F596, this parameter is used to set the start-
time and run-time of Preset Speed 12 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F581
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No
Preset Speed 13 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F597, this parameter is used to set the start-
time and run-time of Preset Speed 13 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F582
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No
Preset Speed 14 Start/Run Time
Program Frequency Preset Speed Time Settings
In conjunction with the setting of F598, this parameter is used to set the start-
time and run-time of Preset Speed 14 when used as part of a Pattern Run.
Settings:
Seconds From Start
Minutes From Start
Seconds From Reach
Minutes From Reach
Infinite (Until Stop Command)
Continue Until Next Step
Direct Access Number — F583
Parameter Type — Selection List
Factory Default Seconds From Start
Changeable During Run — No
F580 F583