E6581595
F-5
6
(1) [ = (Reverse)]: If an F command and an R command are entered simultaneously,
the motor will run in the reverse direction.
Output frequency [Hz]
Forward run
Reverse run
Forward run command
Reverse run command
ON
OFF
ON
OFF
0
Setting frequency
Setting frequency
Time [s]
(2) [ = (Stop)]: If an F command and an R command are entered simultaneously,
the motor will slow down to a stop.
Forward run
Reverse run
Forward run command
Reverse run command
ON
OFF
ON
OFF
Output frequency [Hz]
Setting frequency
Time[s]
0

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required