Page #184 background imageLoading...
Page #184 background image
E6581595
G-9
7
List of output terminal function settings
List of detection levels for output terminal selection
Parameter programmed
value
Function
Parameter
programmed value
Function
Positive
logic
Negative
logic
Positive
logic
Negative
logic
  Frequency lower limit   Small current detection
  Frequency upper limit   Over-torque detection
  Low-speed detection
signal
  Run/Stop
  Output frequency
attainment signal
(acceleration/deceleration
completed)
  Cumulative operation time alarm
  Set frequency attainment
signal
  Forward/reverse run
  Fault signal (trip output)   RS485 communication error
  Over-current pre-alarm   Designated data output
  Overload pre-alarm   Parts replacement alarm
  Overheat pre-alarm   Fault signal
(output also at a ready)
  Overvoltage pre-alarm  Always OFF
  Power circuit
undervoltage detection
 Always ON
Note 1) ON with positive logic : Open collector output transistor or relay turned ON.
OFF with positive logic : Open collector output transistor or relay turned OFF.
ON with negative logic : Open collector output transistor or relay turned OFF.
OFF with negative logic : Open collector output transistor or relay turned ON.
Refer to section 11.7 for details about the output terminal functions or levels.
<Explanation of terminology>
Alarm …... Alarm output when a setting has been exceeded.
Pre-alarm …... Alarm output when the inverter may cause a trip during continued operation.

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required