E6581595
K-9
11
Acceleration/deceleration time parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0500 Acceleration time
2
s 0.1/0.1 0.0-3000 10.0 6.15
0501 Deceleration time
2
s 0.1/0.1 0.0-3000 10.0
0502 Acceleration/decel
eration 1 pattern
- - 0: Linear
1: S-pattern 1
2: S-pattern 2
0
0503 Acceleration/decel
eration 2 pattern
- - 0
0505 Acceleration/decel
eration 1 & 2
switching
frequency
Hz 0.1/0.01 0.0 (disabled)
0.1-
0.0
Protection parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0601 Stall prevention
level 1
%
(A)
1/1
10-199,
200 (disabled)
150
6.16.2
0602
Inverter trip
retention selection
- - 0: Cleared with power off
1: Retained with power off
0 6.16.3
0603 Emergency stop
selection
- - 0: Coast stop
1: Slowdown stop
2: Emergency DC braking
0
6.16.4
0605
Output phase
failure detection
selection
-
-
0: Disabled
1: At start-up (only one time after
power on)
2: At start-up (each time)
0
6.16.5
0607 Motor 150%
overload detection
time
s 1/1 10-2400 300 3.5
6.16.1
0608 Input phase failure
detection selection