E6581595
C-10
3
Operation Command: Panel Operation
Frequency Command: Setting Dial 2
(1) Wiring
(2) Parameter setting
Title Function Programmed value

Command mode selection 1

Frequency setting mode selection 1
(3) Operation
Run/stop: Press the and keys on the panel.
Frequency setting: Turn the setting dial to set the frequency.
To save the frequency setting, press the center of the setting dial.
and the set frequency will flash on and off alternately.
Motor
IM
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
PO
PC/-
PA/+
Operation panel
Ex.2
RUN
STOP

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required

Related product manuals