123
2. Disconnect the wires and remove the coil from the valve.
3. Unsolder the refrigeration lines.
4. Remove the mounting bolts and remove the valve.
Installation
1. Remove the coil from the valve.
2. Place the valve in the unit and install the mounting bolts. The arrow on the valve indicates the direction of flow
through the valve. Verify that the arrow points in the proper direction.
3. Solder the refrigeration lines to the valve.
4. Install the coil and connect the wires.
5. Pressurize the refrigeration system and test for leaks. If no leaks are found, evacuate the system.
6. Recharge the unit with the proper refrigerant and check the compressor oil.
Suction Vibrasorber
Removal
1. Pump down the low side and equalize pressure to slightly positive.
2. Unsolder the suction vibrasorber from the suction service valve.
NNOOTTIICCEE
EEqquuiippmmeenntt DDaammaaggee!!
UUssee aa hheeaatt ssiinnkk oorr wwrraapp EETTVV wwiitthh wweett rraaggss ttoo pprreevveenntt ddaammaaggiinngg tthhee EETTVV..
3. Unsolder the other end of the suction vibrasorber from the ETV and remove the vibrasorber from the unit.
Installation
1. Prepare the suction vibrasorber and tube fittings for soldering by cleaning the thoroughly.
NNOOTTIICCEE
EEqquuiippmmeenntt DDaammaaggee!!
UUssee aa hheeaatt ssiinnkk oorr wwrraapp vviibbrraassoorrbbeerr wwiitthh wweett rraaggss ttoo pprreevveenntt ddaammaaggiinngg tthhee vviibbrraassoorrbbeerr..
2. Solder the vibrasorber to the suction service valve.
NNOOTTIICCEE
EEqquuiippmmeenntt DDaammaaggee!!
UUssee aa hheeaatt ssiinnkk oorr wwrraapp EETTVV wwiitthh wweett rraaggss ttoo pprreevveenntt ddaammaaggiinngg tthhee EETTVV..
3. Solder the other end of the suction vibrasorber to the ETV.
4. Pressurize the low side and check for leaks. If no leaks are found, evacuate the system.
5. Open the refrigeration valves and place the unit in operation.
High Pressure Cutout Switch
Removal
1. Pump down the low side and equalize the pressure to slightly positive.
2. Front seat the discharge and suction service valves. Recover the refrigerant remaining in the compressor.
3. Disconnect the wires and remove the high pressure cutout switch from the compressor discharge manifold.
Installation
1. A new high pressure cutout switch does not have a connector installed. Use the old connector and just install new
RReeffrriiggeerraattiioonn SSeerrvviiccee OOppeerraattiioonnss