14. Remove the 4 drive end bracket M12 bolts.
15. Lower the CMG with the fork truck and remove.
Battery
Maintenance Free Batteries
1. Inspect/clean the battery terminals and check the electrolyte level using the integrated sight glass during scheduled
maintenance inspections.
2. A dead or low battery can be the cause of the ammeter indicating discharge by the DCDC Charger not enabled even
after the unit has been boosted for starting.
Battery Load Test
1. Verify battery voltage of at least 12.5v before load testing.
2. Apply 50% Cold Cranking Amps (CCA) load for 15 seconds and verify minimum voltage of 9.6v.
Battery Cables
The units use 0-gauge battery cables to ensure reliable starting in extremely cold weather. Verify the use of the 0-gauge
battery cables when replacing the battery cables. Refer to the unit Parts Manual for the correct part numbers.
AGM Battery
The lead-acid battery is a thermodynamically unstable system and this is the reason for selfdischarge.