CONDITION POSSIBLE CAUSE REMEDY
High oil consumption 10 hour engine break in running was not
successfully completed
Run unit for 10 hours on high speed continuous run
with trailer doors open as described in the “Unit Check
List” section at the end of the appropriate Installation
Manual
Oil leakage Check and eliminate possible causes at rocker arm
cover, oil lines, oil filter, front timing cover, or
crankshaft seals
Damaged valve seals Replace seals on valve stem
Worn valve stem Replace valves
Broken piston rings or cylinder bore worn
or scored
Have engine repaired and rebored. Replace broken
piston rings
Clogged air cleaner system Unclog air cleaner
Engine Emits Excessive Smoke
White Smoke Black Smoke Blue Smoke
Fuel is not burning Excessive Fuel to Air Ratio Oil Consumption
Air or water in fuel
Incorrect timing
Poor compression
Faulty injectors
Type of fuel used
Cold engine
Excessive load
Clogged air intake system
Faulty nozzles
Poor compression
Restricted exhaust
Faulty injection pump
Poor compression
Defective valve seals