Safety
No Name Description
1 Laser area (working surface /
operating range of the laser)
The laser area is a defined area in which the value of the
maximum permissible exposure (MPE: 1000W/M²) of laser
radiation may exceed or may leak laser radiation. The laser
area consists of the working surface and the operating range of
the laser circular area of approx. ø 5cm (1.97 inch) below the
laserhead.
2 Working area of the operator The safe working area (laser class 2 ; US class II) consists of
the space requirements of the machine and a distance of min.
one meter (39.37 inch) around the machine.
ENGLISH (Translation) 19