Setup and installation
6.2 Operating environment
Subsoil conditions
Conditions:
■
Planarity ±5 mm (±0.1969 inch)
■
Solid, firm and vibration-free soil.
■
Easy-care and clean floor.
■
Bearing capacity of the subsoil ≥1000kg/m2 (10KN/m2)
■
Machine point load 500kg/m² (5KN/m2)
■
No special substrate preparation required.
Environmental conditions
Conditions:
■
Provide sufficient illumination at the workplace.
■
Ensure a dust-free environment (II° according to IEC60947-1)
■
Shielding from EMC.
■
Freedom of interfering electrical installations, hoses and pipe lines.
■
Punktbelastung Maschine 500kg/m² (5KN/m2)
■
Power supply free of fluctuations.
6.2.1 Temperature and humidity
Ambiente conditions
Operating temperature (ambiente temperature): +15 °C to +25 °C
Relative humidity: 45-65%, non-condensing
■
If the system has been exposed to large temperature fluctuations, it must first be brought back to room
temperature before commissioning.
ENGLISH (Translation) 55