Maintenance
Notice
In order to ensure the maximum availability and lifetime of the system, we recommend that you
regularly check the filter, ventilation and exhaust slots and keep the surrounding area clean. A
visual inspection of the lenses is likewise recommended before switching on the system.
9.3 Cleaning
9.3.1 Machine
1. Move the X-axis into a position in which it is easiest for you to clean the surface and interior of the
machine with a window cleaning agent and paper towels
2. Switch off and disconnect the machine from the mains.
3. Remove the tables.
4. Thoroughly remove all loose dirt particles and deposits in the interior of the machine (e.g. with a vacuum
cleaner or broom).
5. Clean the vent slots of the exhaust box inside the machine using a dry or damp cloth, broom or vacuum
cleaner.
6. Clean the cover elements and panels using a dry or slightly damp cotton cloth. Do not use paper towels
as they could scratch the acrylic.
9.3.2 Optics in general
Trotec Laser GmbH recommends to use the cleaning set enclosed. Alternatively, use high-quality cotton
swabs together with the provided cleaning liquid.
Notice
The following cleaning products are available as accessory parts:
– Lens cleaning cloth (Part number 69249)
– Lens cleaning liquid (Part number 69248)
– Bellows (Part number 80779)
ENGLISH (Translation) 85