2.6.3 Emergency stop button
The machine has five emergency stop buttons. When pressing an emergency stop button the electric circuit
immediately shuts off. The laser beam is interrupted, and all movements are stopped.
The function of the emergency laser stop device is:
Firstly: To prevent any risks to the operating personnel.
Secondly: To avoid any damage to or destruction of the machine or material.
2.6.4 Casing elements, side panel and covers
Casing elements, covers and side panels protect from laser light and must always be closed and properly
attached.
2.6.5 Warning lamp
The warning lamp sends out visual signals.
RED GREEN Yellow Description
flashing permanent flashing permanent flashing permanent
Open Interlock
Error
Busy-mode: data processing or
receiving
Pause-mode
Idle-mode: machine is ready. Fully
functional safety devices.
Referencing
Test pulse
Notice
If no LED is lit, the machine is in Standby-mode.