Safety
2.6.10 In case of safety device malfunction
Warning
Danger from laser beam.
Safety and protection devices that are not installed or are not fully functional can lead to bodily
injury and material damage.
– Do not remove, modify or deactivate the interlock safety switches or protective covers on
the machine. Safety and protection devices must be fully functional at all times.
– In case of assumed or presumed damage of safety devices, disconnect the machine from
the mains.
– Damaged safety and protection devices need to be replaced by a Trotec technician
immediately.
2.7 Tests to be carried out
Requirement
The test described below concerns the sensors installed on the machine and must be carried out by a
person instructed by Trotec before each shift, at the latest after 8 hours of operation, to ensure the correct
functioning of all safety-relevant components.
Should errors or functional deviations occur as a result of the test, the machine is deemed not to be ready for
operation and must not be put into operation until the cause has been clarified!
Non-observance can lead to injuries or damage to the machine!
If you have any questions, contact our experienced Technical Support in your local area.
General test procedure for sensors
1. Switch on the machine and have it referenced.
2. Check the corresponding sensors (see table) by manual interruption.
3. The indicator lamp must light up red during the entire duration of the test!
4. Remove the hand from the sensor area to release it again.
5. The display of the signal lamp must light green! In addition, an acoustic warning signal must sound within
5 seconds.