5–10
Enter the distance from the centerline and press
〈ENTER/START〉. The gauge displays:
Left or Right
of Center Line?
1. Left
2. Right
Press 〈1〉 if the station was to the left of the centerline or 〈2〉 if
the station was to the right.
The gauge stores the measurement data and notes under the
selected project and returns to the previous screen.
AVERAGING OR SEGREGATION MODE
After taking a measurement in averaging or segregation mode, the
operator can store the data in the selected project by pressing the
〈STORE〉 key when the gauge displays the test results or after
returning to the Ready screen. The gauge displays:
Do You Want To
Add Notes?
<YES> or <NO>
f Press 〈NO〉 to store only the measurement results under the
active project and return to the previous screen.
f Press 〈YES〉 to include project notes along with the
measurements results. The gauge displays:
Input Location
Press <ENTER>
Enter any desired information (up to eight characters) and press
〈ENTER/START〉. The gauge stores the test results and notes
under the active project and returns to the previous screen.