EasyManua.ls Logo

Tusa ELEMENT - DELAYED VIOLATION MODE #1

Tusa ELEMENT
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
DELAYED VIOLATION MODE #1 (Fig. 38)
If you remain above a required Deco Stop Depth for more than
5 minutes, the full NiBG as well as Total Ascent Time and the
Down Arrow and STOP bar icons will flash until you descend
below the Required Stop Depth. This is a continuation of a
Conditional Violation.
DELAYED VIOLATION MODE #2 (Fig. 39)
The Element cannot calculate decompression times for Stop
Depths much greater than 60 FT (18 M) and offers no indication
of how much time spent underwater would result in the need for
a greater Stop Depth.
If your Decompression obligation requires a Stop Depth between
60 FT (18 M) and 70 FT (21 M), the all segments of the NiBG
will flash. Total Ascent Time will still be displayed.
You must ascend to just deeper than, and stay as close as
possible to 60 FT (18 M) without causing the Total Ascent Time
display to flash.
When the Required Stop Depth indicates 50 FT (15 M), etc., you
can ascend to those depths and continue decompressing.
Fig. 38 - DELAYED
VIOLATION #1 MAIN
Fig. 39 - DELAYED
VIOLATION #2 MAIN