61
CAN BE USED AS
Air Computer
Nitrox Computer
DIVE COMPUTER PERFORMANCE
Buhlmann ZHL-16c based Pelagic Z+ algorithm
No Deco limits closely follow PADI RDP
Decompression in agreement with Buhlmann
ZHL-16c and French MN90
No Deco Deep Stops - Morroni, Bennett
Deco Stops (not recommended) - Blatteau,
Gerth, Gutvik
Altitude - Buhlmann, IANTD, RDP (Cross)
Altitude corrections and O2 limits based on
NOAA tables
OPERATIONAL MODES
Activation/Diagnostic
Serial Number
Surface
Time to Fly Countdown
Desaturation Countdown
Pre Dive Planner
30 to 190 FT (9 to 57 M)
Dive Log (Preview, Dive Data, O2 Data)
Reset
Set FO2 (Air, 21 to 50%)
Set Wet Activation (On / Off)
Set Units of Measure (Imperial / Metric)
Set Hour Format (12 / 24)
Set Time (Hour, Minute)
Set PO2 Alarm (1.20 to 1.60 ATA)
Set FO2 50% Default (On/Off)
No Decompression Dive:
Main
Alt # 1
Alt # 2 -only if nitrox dive
Deep Stop - for dives deeper than 80 FT (24 M)
Safety Stop - for dives deeper than 30 FT (9 M)
Decompression Stop:
Main
Alt # 1
Alt # 2
Alt # 3 - only if a nitrox dive
Violation - Conditional, Delayed # 1, # 2, and # 3
High PO2
High O2