Search and Close Call Options
On The scanner automatically applies repeater reverse to
detected transmissions. If the scanner detects the trans-
mission on the output frequency, it beeps and
displays Repeater Found and remains on the output
frequency until transmissions end. If it does not detect a
transmission on the output frequency, it remains on the
original frequency.
Off The scanner does not try to find the output frequency.
Setting the Maximum Auto Store
Value
  Srch/CloCall Opt E
Max Auto Store E
This value sets how many hits the scanner will automati-
cally store when it is in either Search and Store or Close
Call Auto Store mode.
Use the number keys to enter a value from 1 - 256, then
press E.
When the scanner reaches the maximum number of hits
you set, it stops the auto-store operation.
Setting the Modulation Type
  Srch/CloCall Opt E
Set Modulation E
This setting controls the modulation type used for quick
search and Close Call operations. Select your setting, then
press E.
Auto Uses the default setting for the current frequency
(see the table at the front of the manual)
AM Uses AM (amplitude modulation)
FM Uses FM (frequency modulation)
NFM Uses narrowband FM