Operation
35
6.3.1.2 Automatic dosing (optional)
1. Open the lid closures of the feed container.
2. Press the key on the operating panel for approx. 2 seconds to
switch on the control. The displays shows the
start window:
3. Press and hold the key (approx. 2 seconds).
The Milk Shuttle selects the dosing amount last used
off:
4. Use the preselection keys (see Figure 4/3 on page 16) to choose from three
pre-programmed feed amounts. Choose , or if you require a
different feed amount. How to program the preselection keys with your own
values is described in chapter 7.4, page 53.
When delivered, the preselection keys are assigned the following feed
amounts:
5. Use the / keys to individually change the dosing amount during
feeding. These changes are not saved. If you exit the Feeding menu with this
value, it is retained and displayed at the next start.
6. Take the pump nozzle from the drawbar holder and hold it over the intended
container.
7. Actuate the trigger
1
of the pump nozzle; the feed pump starts and pumps the
required feed amount into the container. Once the feed amount is dosed out,
release the pump nozzle trigger, move the Milk Shuttle to the next container
and actuate the pump nozzle trigger again.
8. In addition to the set dosing amount, the display
shows the already dosed amount
9. You can cancel feeding with the key.
10. If you briefly press the key during the dosing procedure,
you can check the flow behaviour of the
flow rate controller:
The calculated values are displayed.
Preselection key Feed amount
2 litres (or 2 kg)
3 litres (or 3 kg)
4 litres (or 4 kg)
16.07.14 10:30:32
MilkShuttle 105A31
Feeding █████
1: 04,0 █████
-
Feeding █████
1: 04,0 02,1 █████
03,0 160 Pulses
02,1 160 Pulses