What if...
63
Troubleshooting
When this fault appears the fill level of the
MilkShuttle container needs to be checked:
If the filling quantity in the MilkShuttle
container is below the minimum fill level, fill
the container with milk or water until the
minimum fill level has been reached.
If the fill quantity in the MilkShuttle container
is above the minimum fill level:
switch on the agitator in order to mix the
liquid in the container and thereby create
even heat dissipation inside the container.
check that the agitator is functioning
properly.
If this fault repeatedly occurs it may be
appropriate to set the tolerance barrier against
low fill level of the container to the value high.
Fault description
Fault messages with the fault code 50 to 52
indicate insufficient heat dissipation from the
MilkShuttle's container base. In this case, the
central control stops the MilkShuttle from
operating in order to prevent the heating
element from overheating.
Display message
50 Fault
Low milk level
51 Fault
Low milk level
52 Fault
Low milk level
No.
Type
50
2
51
2
52
2