What if...
64
Troubleshooting
• Insert the power plug.
• Check the fuses and the residual current device of the electric
installation
• Assure the clockwise phase sequencing of the electrical rotary field.
In case of an anti-clockwise phase sequencing, switch the phases
L1 and L2 by means of the phase changing switch of the connecting
cable
• Assure that the mains voltage is neither too low nor too high.
• Connect Milk Shuttle II to mains voltage for charging as soon as
possible.
• Fill Milk Shuttle II.
• Rinse Milk Shuttle II with detergent.
• Clean flow rate controller by hand.
• If nothing changes after cleaning, deactivate the flow rate controller:
Call up the "Feed" function and then press both "Plus" and "Minus"
keys at the same time. "Flow r. controller deactivated"
appears briefly in the display. When the flow rate controller is
deactivated, the Milk Shuttle II works according to time dosing. After
changing to time dosing, calibrate the Milk Shuttle II (see
chapter 7.2.1).
• Activating the flow rate controller is also done by pressing both
"Plus" and "Minus" keys at the same time in the "Feed" function.
Fault description
Function cannot be
executed because
there is no mains
voltage present.
The battery voltage is
weakening.
Battery 1 under 12.2 V
and/or
Battery 2 under 24.4 V
While dosing, the flow
meter did not transmit a
pulse during the last 5
seconds. The Milk
Shuttle II is empty, or
the flow meter is
contaminated and is
thus not measuring
correctly.
Display message
60 Fault
No mains voltage
70 Battery low!
72 Sensor faulty?
No.
Type
60
2
70
3
72
3